1. Dismantle details of the unit which disturb access to the corresponding cover of cast openings. |
2. Establish a screw-driver or a narrow chisel on the cover region. |
|
3. Carefully drive in inside a locking cover (121) on the one hand until it will not turn on 90 °. |
|
4. The turned cover extend by means of a trumpet key. |
|
5. Carefully clear a cast opening of deposits. The sealing surface (arrow) should be cleared of deposits. |
6. Cover a sealing surface with hermetic (for example, Loctite N241 or Curil). |
|
7. Drive a new locking cover the suitable probe. Let's harden to hermetic according to the instruction of the manufacturer (about 45 minutes). |
8. Establish the dismantled parts of the unit. |
9. Fill in cooling liquid. |
10. Warm up the engine, check level of cooling liquid and tightness of covers of cast openings. |